Tool |
Timeout |
Keypad Number |
Internal ID number |
Drill Press 1 |
5 min |
1 |
13 |
Drill Press 2 |
5 min |
2 |
18 |
Metal Bandsaw |
5 min |
3 |
11 |
Wood Bandsaw |
5 min |
4 |
17 |
Mill |
15 min |
5 |
14 |
CNC |
1 hour |
6 |
12 |
Mill¶
- The mill machine switch cuts both hot and neutral
Tooltron Configuration¶
- Tooltron board ID: 4
- tooltron is connected after the switch on the neutral line (between switch and motor)
- a hot line is also running through the mill for the current sense after the switch
- test line is hot when switch is on regardless of motor spinning
Wiring¶
- green/yellow: earth ground
- blue from wall -> red in machine: right prong when facing male plug w/ ground @ bottom (should be neutral at wall)
- brown from wall -> black in machine: left prong when facing plug (should be hot at wall)
Seems to follow european coloring standards:¶
- The live conductor must be brown
- The neutral is blue
- The earth ('safety ground') must be green/yellow
Drill Press 1¶
- The drill press close to the door
- Board ID: 3
Drill Press 2¶
- The drill press closer to the wall
- Board ID: 8