Project

General

Profile

Tool Timeout Keypad Number Internal ID number
Drill Press 1 5 min 1 13
Drill Press 2 5 min 2 18
Metal Bandsaw 5 min 3 11
Wood Bandsaw 5 min 4 17
Mill 15 min 5 14
CNC 1 hour 6 12

Mill

  • The mill machine switch cuts both hot and neutral

Tooltron Configuration

  • Tooltron board ID: 4
  • tooltron is connected after the switch on the neutral line (between switch and motor)
  • a hot line is also running through the mill for the current sense after the switch
    • test line is hot when switch is on regardless of motor spinning

Wiring

  • green/yellow: earth ground
  • blue from wall -> red in machine: right prong when facing male plug w/ ground @ bottom (should be neutral at wall)
  • brown from wall -> black in machine: left prong when facing plug (should be hot at wall)

Seems to follow european coloring standards:

  • The live conductor must be brown
  • The neutral is blue
  • The earth ('safety ground') must be green/yellow

Drill Press 1

  • The drill press close to the door
  • Board ID: 3

Drill Press 2

  • The drill press closer to the wall
  • Board ID: 8